Hydrogenated Styrenic Thermoplastic Eastomer (SEBS) Tuftec™ H1043
Applications
Physical Form
- Supplied as a dusted, dence pellet
Features and Benefits
- Good compatibility to COP and COC
- Good compatibility to PPE
Regulations
- FDA 21 CFR 177.1810
- Regulation (EU) No 10/2011
Characteristics
Property | Test Method | Unit | Value |
---|---|---|---|
Specific Gravity | ISO 1183 | g/cm3 | 0.97 |
MFR 230°C, 2.16kg Load | ISO 1133 | g/10 min | 2.0 |
Hardness Durometer Type D |
ISO 7619 | °Shore D | 72 |
Tensile Strength Dumbbell: Type 1A 10 mm/min |
ISO 37 | MPa | 10.3 |
Elongation Dumbbell: Type 1A 10 mm/min |
ISO 37 | % | 20 |
Styrene / Ethylene-Butylene Ratio | Asahi Kasei Metdod | 67/33 |
Typical characteristics of HIPS/PP/H1043 blend (injection molded parts)
Property | Test method | HIPS/PP 70/30 |
HIPS/PP/H1041 70/30/6 |
HIPS/PP/H1043 70/30/6 |
---|---|---|---|---|
Specific gravity | ASTM D 297 | 0.99 | 0.99 | 0.99 |
MFR (g/10 min) 200°C, 5 kg load |
ASTM D 1238 | 25 | 13 | 13 |
Tensile strength (MPa) 5 mm/min |
ASTM D 638 | 26.5 | 23.5 | 28.4 |
Elongation (%) 5 mm/min |
ASTM D 638 | 3 | 16 | 170 |
Flexural strength (MPa) 3 mm/min |
ASTM D 790 | 46 | 40 | 46 |
Flexural modulus (MPa) 3 mm/min |
ASTM D 790 | 1860 | 1570 | 1770 |
Izod impact strength (kgcm/cm) | ASTM D 256 | 4.4 | 11.2 | 7.2 |
Heat distortion temp. (°C) 4.6 kg load |
ASTM D 648 | 91 | 89 | 89 |
Vicat softening point (°C) | ASTM D 1525 | 110 | 108 | 108 |
Please note that all data and values are given as typical results obtained with the indicated test methods for purposes of basic reference in grade selection only, and not as any product specification or warranty of any nature, and are subject to change without notice.
Please refer to Terms and Conditions and Privacy Policy
IMPORTANT NOTICE REGARDING MEDICAL APPLICATIONS
We, Asahi Kasei Group, request that customers who are considering using our products in medical, pharmaceutical, cosmetic and other related applications (hereinafter collectively called “Medical Applications”) shall contact us and confirm our policy on Medical Applications in advance. Information herein regarding conformity to certain laws and regulations are as of January, 2015. Please consult with us for the latest status. We make no guarantees or warranties, express or implied, concerning the suitability of our products for use in Medical Applications. It is not our responsibility to determine if our products are safe, lawful, and technically suitable for intended applications.