What's new Home Contact us Products Tech guide Applications Japanese Reports Elastomers AsaflexTM
Home > Tech Guide > Typical polypropylene modification by Tuftec™ H1041
Tech guide Elastomers
May 26, 2010


Tuftec™ H1041 is effective for polypropylene modification. As the content of H1041 increases in PP block copolymer/H1041 blends, polypropylene becomes softer, and the low temperature impact strength improves.
Determine the composition ratio depending upon the balance of targeted rigidity and impact strength.

 
Typical polypropylene modification by Tuftec™ H1041
Effects of Tuftec™ H1041 blending with polypropylene
 
PP block copolymer/H1041
Property Test method 100/0 85/15 70/30 55/45

MFR (g/10 min)

ASTM D 1238 (230°C, 2.16 kg load)
1.9 2.3 2.9 3.9
Tensile yield strength (MPa)
ASTM D638
23 22 17 14
Tensile elongation at break (%) 700 600 570 540
Flexural yield strength (MPa)
ASTM D 790
23°C
34 26 19 15
50°C
20 15 11 8
80°C
12 9 6 4

Flexural modulus (MPa)

ASTM D 790
23°C
1,200 850 640 450
50°C
640 490 350 240
80°C
390 280 200 130
Izod impact strength* (J/m)
ASTM D 256
23°C
150 NB NB NB
0°C
61 NB NB NB
10°C
52 NB NB NB
30°C
45 82 NB NB
40°C
43 69 NB NB
Hardness (Shore D)
ASTM D 1706
72 68 63 56
*NB: Non-break
  • Please note that all data and values are given as typical results obtained with the indicated test methods,
    and not as any product specification or warranty of any nature.

To top
Contact us Term Privacy Site Map About Us Home