| Home > Tech Guide
> Tuftec H Compatibilization of HIPS and PP |
 |
 |
December
12, 2001
|
 |
Tuftec
H Compatibilization of HIPS and PP
The Tuftec H series
provides extremely high compatibilization of differing
polymers, as indicated by these TEM micrographs and test
results for injection molding and sheet extruding of formulations
with Tuftec H1041
and Tuftec H1043.
TEM micrographs Effect of
Tuftec addition on HIPS/PP morphology
|
|
|
|
|
HIPS/PP (70/30)
|
|
|
Matrix: HIPS (dark areas); Dispersed particles:
PP
Samples: Ruthenium-stained ultrathin sections of
extruded sheets (0.7 mm). |
Injection molding test
results
| Property |
Units |
Test method |
Test conditions |
HIPS |
PP |
HIPS/PP
70/30 |
HIPS/PP/H1041
70/30/6 |
HIPS/PP/H1043
70/30/6 |
| Specific
gravity |
-- |
ASTM D
297
|
--
|
1.05
|
0.90
|
0.99
|
0.99
|
0.99
|
| MFR |
g/10
min |
ISO 1133
|
200°C,
5 kg load
|
6.6
|
8.5*
|
25
|
13
|
13
|
| Tensile
strength |
MPa |
ASTM D 638 |
5 mm/min
|
30.4
|
26.5
|
26.5
|
23.5
|
28.4
|
| Elongation |
% |
5 mm/min
|
19
|
>200
|
3
|
16
|
170
|
| Flexural
strength |
MPa |
ASTM D
790
|
3 mm/min
|
52
|
31
|
46
|
40
|
46
|
| Flexural
modulus |
MPa |
3 mm/min
|
2,260
|
1,080
|
1,860
|
1,570
|
1,770
|
| Notched
Izod impact strength |
kgcm/cm |
ASTM D
256
|
--
|
7.5
|
12.0
|
4.4
|
11.2
|
7.2
|
| Heat
distortion temp. |
°C |
ASTM D
648
|
4.6 kg
load
|
87
|
105
|
91
|
89
|
89
|
| Vicat
softening point |
°C |
ASTM
D 1525
|
1 kg load
|
106
|
150
|
110
|
108
|
108
|
|
Sheet extrusion test
results (thickness, 0.7 mm)
| Property |
Units |
Test
conditions |
HIPS |
HIPS/PP
70/30 |
HIPS/PP/H1041
70/30/6 |
HIPS/PP/H1043
70/30/6 |
| Dupont
impact strength |
J
|
Drop weight
136.5 g
5 mm dia.
|
12
Ductile-brittle fracture
|
0.5
Brittle fracture
|
11
Brittle fracture
|
23
Ductile fracture
|
| Surface
gloss |
%
|
Gloss 60-degree
|
30
|
41
|
51
|
68
|
| Oil
resistance |
--
|
Synthetic
coconut oil
100°C, 10 min
|
Deformation
Partially dissolved
|
Good
|
Good
|
Good
|
|
|
|
- Please note that all data and values
are given as typical results obtained with the indicated
test methods,
and not as any product specification or warranty of any
nature.
|
To top |
|